{"product_id":"pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-10m-a-r-32-monofase-a7794573-con-pannello-di-comando-remoto-incluso-novita","title":"Baxi AURIGA 10M-A R-32 Single Phase Inverter Air-Water Monobloc Heat Pump A7794573 with Remote Control Panel Included - New","description":"\u003cp\u003e \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cstrong\u003eATTENTION ! IN CASE OF NO IMMEDIATE AVAILABILITY, THE PRODUCT WILL BE ORDERED AND SHIPPED WITHIN 10 WORKING DAYS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eFIRST STARTING INCLUDED!\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eTechnical features\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Model: Auriga 10M-A\u003c\/li\u003e\n\n\u003cli\u003e Product Code: \u003cspan\u003eA7794573\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e Remote Control Panel \u003cspan\u003eA7799122\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eHeating with low temperature application\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cem\u003eExternal air temperature 7°C - 87% RH Water temperature 30\/35°C\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n \u003cli\u003eNonimal thermal power: 10.00 kW\u003c\/li\u003e\n\n\u003cli\u003e Electrical power absorbed: 2.02 kW\u003c\/li\u003e\n\n\u003cli\u003e COP: 4.95\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdiv\u003e\n\n\u003cp\u003e \u003cem\u003eExternal air temperature 7°C - 87% RH Water temperature 35°C\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Normal heating power: 8.00 kW\u003c\/li\u003e\n\n\u003cli\u003e Electrical power absorbed: 2.62 kW\u003c\/li\u003e\n\n\u003cli\u003e COP: 3.05\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eHeating with medium temperature application\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003cp\u003e \u003cem\u003eExternal air temperature 7°C - 87% RH Water temperature 45°C\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Nonimal thermal power: 10.00 kW\u003c\/li\u003e\n\n\u003cli\u003e Electrical power absorbed: 2.67 kW\u003c\/li\u003e\n\n\u003cli\u003e COP: 3.75\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdiv\u003e\n\n\u003cp\u003e \u003cem\u003eExternal air temperature 7°C - 87% RH Water temperature 55°C\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Non-normal thermal power: 9.50 kW\u003c\/li\u003e\n\n\u003cli\u003e Electrical power absorbed: 3.06 kW\u003c\/li\u003e\n\n\u003cli\u003e COP: 3.10\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cp\u003e \u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cem\u003eExternal air temperature 35°C - Water temperature 18°C\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Average cooling capacity: 9.90 kW\u003c\/li\u003e\n\n\u003cli\u003e Electrical power absorbed: 2.18 kW\u003c\/li\u003e\n\n\u003cli\u003e EER: 4.55\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdiv\u003e\n\n\u003cp\u003e \u003cem\u003eExternal air temperature 35°C - Water temperature 7°C\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Average cooling capacity: 8.20 kW\u003c\/li\u003e\n\n\u003cli\u003e Electrical power absorbed: 2.52 kW\u003c\/li\u003e\n\n\u003cli\u003e EER: 3.25\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eEnergy efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n \u003cli\u003eSeasonal energy efficiency of low temperature space heating: 205%\u003c\/li\u003e\n\n\u003cli\u003e Seasonal energy efficiency of medium temperature space heating: 137%\u003c\/li\u003e\n\n\u003cli\u003e Low temperature seasonal energy efficiency class: A+++\u003c\/li\u003e\n\n\u003cli\u003e Medium temperature seasonal energy efficiency class: A++\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Exchanger water flow rate: 1.73 m \u003csup\u003e3\u003c\/sup\u003e \/h\u003c\/li\u003e\n\n\u003cli\u003e Useful pump head: 70 kPa\u003c\/li\u003e\n\n\u003cli\u003e Sound power level: 60 dB(A)\u003c\/li\u003e\n\n\u003cli\u003e Sound pressure level: 50.5 dB(A)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eElectrical Data\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Power (V,Hz, Ø): 220~240\/50\/1\u003c\/li\u003e\n\n\u003cli\u003e Refrigerant gas: R32\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdiv\u003e\n\n \u003cstrong\u003eOperation limits\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003cem\u003eHeating\u003c\/em\u003e\n\u003c\/div\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e External air temperature: -25°C ~ 35°C\u003c\/li\u003e\n\n\u003cli\u003e Introduced water temperature: 12°C~ 65°C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdiv\u003e \u003cem\u003eCooling down\u003c\/em\u003e\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e External air temperature: -5°C ~ 43°C\u003c\/li\u003e\n\n\u003cli\u003e Introduced water temperature: 5°C ~ 25°C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e \u003cstrong\u003eInstallation Data\u003c\/strong\u003e\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Hydraulic pipe diameter: 1'' 1\/4\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Dimensions (HxWxD): 865x1385x488 mm\u003c\/li\u003e\n\n \u003cli\u003eEmpty weight: 121 kg\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cspan\u003e\u003cstrong\u003eBAXI AURIGA Monobloc Inverter Air-Water \u003ca title=\"Heat pumps\" href=\"https:\/\/www.climaconvenienza.it\/it\/altri-sistemi-di-climatizzazione-e-ventilazione\/\" rel=\"noopener\" target=\"_blank\"\u003eHeat Pumps\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e introducing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enew Charioteer\u003c\/strong\u003e . The range is characterized by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eease and simplicity of installation, as well as for reliability and excellent performance\u003c\/strong\u003e . Furthermore, the high prevalence of the circulator, mounted AS STANDARD inside the unit, allows installation in large systems, to cover greater distances from the boiler room or to install the unit directly at the service of the fan coils. The range is expanding and is made up of many more\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 models from 4 to 16 kW, single-phase and three-phase versions\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan\u003e\u003ciframe width=\"600\" height=\"450\" style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/www.climaconvenienza.it\/pimages\/FCKeditorFiles\/Image\/AURIGA.mp4\" data-mce-fragment=\"1\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWide power range from 4 to 16 kW\u003c\/strong\u003e to satisfy all system needs: heating, cooling and DHW production. The power range is made up of the following sizes: 4, 6, 8, 10, 12 and 16 kW.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eCascade\u003c\/strong\u003e Thanks to the new operating logics it is possible to install up to 6 units in cascade. By taking advantage of the modularity and redundancy of the generators, the system efficiently satisfies the demands of all systems.\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eComplete standard hydraulic equipment\u003c\/strong\u003e High head circulation pump, flow switch, expansion vessel (8L), safety valve, pressure gauge and \"Y\" filter\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eRemote control panel\u003c\/strong\u003e Control of system functions, programming and verification of parameters. Furthermore, the possibility of connection via Modbus allows integration with BM systems\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eOperating range\u003c\/strong\u003e Wide operating range, with operating temperatures in heating up to 65 °C\u003c\/p\u003e\n\n \u003cp\u003e\u003cstrong\u003eErP Energy Labeling\u003c\/strong\u003e The labeling regulation (EU Regulation 2017\/1369) requires products to be labeled according to a decreasing energy scale ranging from A+++ to D (in heating) and from A+ to F (in sanitary). All models in the range (4M-A \/ 6M-A \/ 8M-A \/ 10M-A \/ 12M-A \/ 12T-A \/ 16M-A \/ 16T-A) reach an efficiency equal to A+++ in low temperature heating\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eComponents\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eTwin rotary DC inverter compressor\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eComplete with internal thermal protection and crankcase heater, mounted on anti-vibration rubbers and wrapped in insulating caps to reduce the transmission of noise and vibrations due to operation\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eWater-refrigerant exchanger\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith brazed plates in AISI 316 steel with external anti-condensation insulation in expanded polypropylene and antifreeze resistance to avoid the formation of ice in the exchanger\u003c\/p\u003e\n\n \u003cp\u003e\u003cstrong\u003eAir-refrigerant exchanger\u003c\/strong\u003e Finned aluminum coil with hydrophilic treatment to facilitate condensate flow, mechanically expanded copper tubes with internal shaping to increase heat exchange. Furthermore, the optimized circuitry allows the formation of ice in the coil to be reduced during heat pump operation\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eFan\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaxial directly coupled to the high efficiency brushless DC variable speed motor. The fan is installed on aerodynamic nozzles and safety grilles\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eRefrigerant circuit\u003c\/strong\u003e Made of pickled copper, includes the electronic expansion valve, drier filters, high and low pressure switches, pressure transducer, cycle reversal valves, liquid receiver and separator, refrigerant injection valve on the suction\u003c\/p\u003e\n\n \u003cp\u003e\u003cstrong\u003eHydraulic circuit\u003c\/strong\u003e In addition to the brazed plate exchanger, the unit includes the high head circulator, the expansion vessel, the safety valve, the flow switch, the pressure gauge, the air vent valve and the metal mesh Y-filter (assembly by the installer)\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong\u003eElectrical panel\u003c\/strong\u003e Includes fuse protection of the main internal components; the terminal block is divided into a power section for powering the unit and a control terminal block for connecting auxiliary inputs and outputs and connection to the control panel\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cstrong\u003eMain features Baxi Auriga\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Maximum energy efficiency\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Monobloc system for the production of heating, cooling and DHW\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Wide operating range, with external air down to -25°C in heating, up to 43°C in cooling\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cul\u003e\n\n \u003cli\u003eManagement of the DHW system: production up to 65°C, management of the boiler temperature, DHW recirculation pump and solar thermal integration\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Suitable for integration with radiant terminals, fan coils and mixed systems\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Integrated management with different system systems: boiler integration, solar integration, management of diverter valves and secondary circuit pump\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Intelligent defrost thanks to the simultaneous monitoring of the ambient temperature, refrigerant temperature, produced water temperature and operating mode\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Compressor with DC inverter technology with high modulation range\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Modbus network connection\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e low GWP refrigerant R32\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e \u003cspan\u003e\u003cstrong\u003eProduct Warranty:\u003c\/strong\u003e All products on sale on our site are new and packaged. The warranty on this item is \u003cstrong\u003e24 months\u003c\/strong\u003e from the date of purchase.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Baxi","offers":[{"title":"Default Title","offer_id":65164502204765,"sku":"A7794573","price":3357.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1090\/1589\/2317\/files\/immagine-1-pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-10m-a-r-32-monofase-a7794573-con-pannello-di-comando-remoto-incluso-novita_724c3248-b7ff-4b77-a8ee-15fa64bfddb3.jpg?v=1783624850","url":"https:\/\/www.deviceoutlet24.com\/products\/pompa-di-calore-aria-acqua-monoblocco-inverter-baxi-auriga-10m-a-r-32-monofase-a7794573-con-pannello-di-comando-remoto-incluso-novita","provider":"Deviceoutlet24","version":"1.0","type":"link"}